Artikel

Sensitive Cd isotopic analysis by multi-collector inductively coupled plasma mass spectrometry using electrothermal vaporization

25.07.2025

Von Wiley-VCH zur Verfügung gestellt

A fast and highly sensitive method for cadmium (Cd) isotopic analysis was developed by coupling electrothermal vaporization (ETV) with multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS). In this approach, a 5 μL Cd sample was dropped onto the W-coil ETV, followed by sequential drying and vaporization. The vaporized analyte was then swept into the MC-ICPMS for isotopic analysis, and the whole analysis process took only 3 min. This system exhibited exceptional sampling efficiency, achieving > 99% Cd vaporization and reducing sample consumption to only 2 ng per analysis, representing a 20-fold improvement over conventional pneumatic nebulization (PN). The ETV transient signals were recorded in time resolved analysis (TRA) mode, and the isotope ratio processing was calculated using the linear regression slope (LRS) method. These ratios were further corrected for instrumental mass bias using a combination of double spike (DS) and standard-sample bracketing (SSB), ensuring high precision and accuracy. Repeated analyses of NIST 3108 and GBW 08612 (in-house standard) yielded δ11/110Cd values of 0.00 ± 0.05‰ (2SD, n  = 12) and − 0.96 ± 0.05‰ (2SD, n  = 12), respectively. Tests on standard samples purified once and twice showed no significant differences, indicating better matrix tolerance over the conventional PN method. This method enables high-throughput Cd isotopic analysis of trace-level environmental samples, facilitating investigations into biogeochemical cycling at low Cd concentrations and pollution source tracing. Graphical Abstract
Verwandte Artikel
Sensitive Cd isotopic analysis by multi-collector inductively coupled plasma mass spectrometry using electrothermal vaporization
In Kürze
Sensitive Cd isotopic analysis by multi-collector inductively coupled plasma mass spectrometry using electrothermal vaporization
Ehrungen, Karriere
Sensitive Cd isotopic analysis by multi-collector inductively coupled plasma mass spectrometry using electrothermal vaporization
Aus den Fachgruppen
Sensitive Cd isotopic analysis by multi-collector inductively coupled plasma mass spectrometry using electrothermal vaporization
EuChemS Policy Workshop „PFAS”
Sensitive Cd isotopic analysis by multi-collector inductively coupled plasma mass spectrometry using electrothermal vaporization
Bafög beantragen

Das könnte Sie auch interessieren

GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

In Kürze

GÖCH

Termin vormerken: Generalversammlung am 21. September Die diesjährige Generalversammlung ist im Rahmen der Chemietage am...

30.04.2026
GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

Ehrungen, Karriere

Service

Ehrungen Finnian Freeling, Dr.: Promotionspreis Wasserchemie der Wasserchemischen Gesellschaft, Fachgruppe der GDCh, für...

30.04.2026
GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

Aus den Fachgruppen

GDCh

Bauchemie Neuer Vorstand Die GDCh-Fachgruppe Bauchemie hat ihren Vorstand für die Amtszeit 1. Januar 2026 bis 31. Dezemb...

30.04.2026