Artikel

Immobilized glucose oxidase on hierarchically porous COFs and integrated nanozymes: a cascade reaction strategy for ratiometric fluorescence sensors

01.08.2022

Von Wiley-VCH zur Verfügung gestellt

Covalent organic frameworks (COFs) with uniform porosity, good stability, and desired biocompatibility can function as carriers of immobilized enzymes. However, the obstructed pores or partially obstructed pores have hindered their applicability after loading enzymes. In this study, the hierarchical COFs were prepared as an ideal support to immobilize glucose oxidase (GOD) and obtain GOD@COF. The hierarchical porosity and porous structures of COFs provided sufficient sites to immobilize GOD and increased the rate of diffusion of substrate and product. Moreover, N,Fe-doped carbon dots (N,Fe-CDs) with peroxidase-like activity were introduced to combine with GOD@COF to construct an enzyme-mediated cascade reaction, which is the basis of the sensor GOD@COF/N,Fe-CDs. The sensor has been successfully built and applied to detect glucose. The limit of detection was 0.59 μM for determining glucose with the proposed fluorescence sensor. The practicability was illustrated by detecting glucose in human serum and saliva samples with satisfactory recoveries. The proposed sensor provided a novel strategy that introduced COF-immobilized enzymes for cascade reactions in biosensing and clinical diagnosis. Graphical abstract
Verwandte Artikel
Immobilized glucose oxidase on hierarchically porous COFs and integrated nanozymes: a cascade reaction strategy for ratiometric fluorescence sensors
In Kürze
Immobilized glucose oxidase on hierarchically porous COFs and integrated nanozymes: a cascade reaction strategy for ratiometric fluorescence sensors
Ehrungen, Karriere
Immobilized glucose oxidase on hierarchically porous COFs and integrated nanozymes: a cascade reaction strategy for ratiometric fluorescence sensors
Aus den Fachgruppen
Immobilized glucose oxidase on hierarchically porous COFs and integrated nanozymes: a cascade reaction strategy for ratiometric fluorescence sensors
EuChemS Policy Workshop „PFAS”
Immobilized glucose oxidase on hierarchically porous COFs and integrated nanozymes: a cascade reaction strategy for ratiometric fluorescence sensors
Bafög beantragen

Das könnte Sie auch interessieren

GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

In Kürze

GÖCH

Termin vormerken: Generalversammlung am 21. September Die diesjährige Generalversammlung ist im Rahmen der Chemietage am...

30.04.2026
GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

Ehrungen, Karriere

Service

Ehrungen Finnian Freeling, Dr.: Promotionspreis Wasserchemie der Wasserchemischen Gesellschaft, Fachgruppe der GDCh, für...

30.04.2026
GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

Aus den Fachgruppen

GDCh

Bauchemie Neuer Vorstand Die GDCh-Fachgruppe Bauchemie hat ihren Vorstand für die Amtszeit 1. Januar 2026 bis 31. Dezemb...

30.04.2026