Artikel

Electrochemical detection of miRNA using commercial and hand‐made screen‐printed electrodes: liquid biopsy for cancer management as case of study

09.02.2024

Screen-printed electrodes are able to offer potent tools for detecting miRNAs in liquid biopsy: commercial or handmade?


Abstract

The growth of liquid biopsy, i. e., the possibility of obtaining health information by analysing circulating species (nucleic acids, cells, proteins, and vesicles) in peripheric biofluids, is pushing the field of sensors and biosensors beyond the limit to provide decentralised solutions for nonspecialists. In particular, among all the circulating species that can be adopted in managing cancer evolution, both for diagnostic and prognostic applications, microRNAs have been highly studied and detected. The development of electrochemical devices is particularly relevant for liquid biopsy purposes, and the screen-printed electrodes (SPEs) represent one of the building blocks for producing novel portable devices. In this work, we have taken miR-2115-3p as model target (it is related to lung cancer), and we have developed a biosensor by exploiting the use of a complementary DNA probe modified with methylene blue as redox mediator. In particular, the chosen sensing architecture was applied to serum measurements of the selected miRNA, obtaining a detection limit within the low nanomolar range; in addition, various platforms were interrogated, namely commercial and hand-made SPEs, with the aim of providing the reader with some insights about the optimal platform to be used by considering both the cost and the analytical performance.

Verwandte Artikel
Electrochemical detection of miRNA using commercial and hand‐made screen‐printed electrodes: liquid biopsy for cancer management as case of study
In Kürze
Electrochemical detection of miRNA using commercial and hand‐made screen‐printed electrodes: liquid biopsy for cancer management as case of study
Ehrungen, Karriere
Electrochemical detection of miRNA using commercial and hand‐made screen‐printed electrodes: liquid biopsy for cancer management as case of study
Aus den Fachgruppen
Electrochemical detection of miRNA using commercial and hand‐made screen‐printed electrodes: liquid biopsy for cancer management as case of study
EuChemS Policy Workshop „PFAS”
Electrochemical detection of miRNA using commercial and hand‐made screen‐printed electrodes: liquid biopsy for cancer management as case of study
Bafög beantragen

Das könnte Sie auch interessieren

GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

In Kürze

GÖCH

Termin vormerken: Generalversammlung am 21. September Die diesjährige Generalversammlung ist im Rahmen der Chemietage am...

30.04.2026
GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

Ehrungen, Karriere

Service

Ehrungen Finnian Freeling, Dr.: Promotionspreis Wasserchemie der Wasserchemischen Gesellschaft, Fachgruppe der GDCh, für...

30.04.2026
GDCh-Mitglieder exklusiv

Artikel • Nachrichten aus der Chemie

Aus den Fachgruppen

GDCh

Bauchemie Neuer Vorstand Die GDCh-Fachgruppe Bauchemie hat ihren Vorstand für die Amtszeit 1. Januar 2026 bis 31. Dezemb...

30.04.2026